EasyManua.ls Logo

Lust CDA3000 - Page 97

Lust CDA3000
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Manual CDA3000
4-45
4 Application data sets
1
2
3
4
5
6
A
DE
EN
FR
4.5.3 BUS_3
Additional emergency operation with limit switch evaluation
Preset 3 for field bus operation
Figure 4.31 Control terminal configuration with ASTER = BUS_3
The parameter presets for application data sets BUS_x are located as
parameter comparison references in section 4.5.4 Comparison of para-
meters, field bus operation.
Function Application
Control of the inverter module over
the field bus
Control of the device in emergency
also independently of bus
Manual/automatic switchover
Evaluation of safety limit switches
Traction and lifting drive
H1 H2 H3
X4
X2
X1
X3
ANTRIEBSTECHNIK
D-35633 Lahnau
L3
U
V
W
RB+
RB
L-
L1
L2
12
345
16 17
18 19 20
11
12 13 14 15
678
9
10
ACHTUNG
Kondensatorent-
ladezeit >3 Min.
Betriebsanleitung
beachten!
WARNING
capacitor disscharge
time >3 minutes.
Pay attention to the
operation manual!
ATTENTION
temps de decharge
du condensteur
>3 min. observer le
mode dèmploi!
!
OPTN2 (X7)
X10
X11
X12
1
2
X2 Des. Function
20 OSD02/14
Relay contact
for Ready mes-
sage
19 OSD02/11
18 OSD02/12
17 DGND Digital ground
16 OSD01 Digital output 2:
15 OSD00 Digital output 1:
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Limit switch left
11 ISD02 Limit switch right
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V
6
U
V
Auxiliary voltage 24 V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Selection of manual mode
2 ISA00
Reference for manual mode
0...10 V
1
U
R
Reference voltage 10V, 10mA
ENPO
S4
STL
STR
S3
N1
-
+
S1
0 ... 10 V
R1
³
10 k
W
+24V
K0
14
11
12

Table of Contents

Other manuals for Lust CDA3000