Maintenance work on the carrier
7.4 Fuel system
7 - 36 3 302 574 en Maintenance manual
GMK3060
03.11.2017
Remove the electrical connecting cable (3)
from the water sensor (WIF = Water in Fuel).
Remove the filter (1).
Screw on a new filter (1) and tighten it.
Close the valve (2) manually.
Attach the electrical connecting cable (3) to
the water sensor (WIF = Water in Fuel).
Actuate the pump (2) until the fluid flowing
out of the drain plug (1) no longer contains
any bubbles.
Close the drain plug (1).
Start the engine and check for leaks.
Remove the receptacle.
H
If you have used a clean receptacle, you can refill the fuel tank with the
consumable using a filter.
Otherwise dispose of the consumable properly.