Run-in regulations
03.11.2017
Maintenance manual 3 302 574 en 4 - 1
GMK3060
4 Run-in regulations
There are regulations about running in individual parts which must be
followed, after:
– First commissioning or
– Part replacement or
– General overhaul.
This is why
you must carry out additional main
tenance work on
the carrier
and superstructure at specific intervals:
s
Operating
hours
(oper. hrs.)
Driven km
(mi)
Additional maintenance work on the
CARRIER
After 50 (30)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
After 150
(95)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 50 Tighten the clips on the coolant hoses;
à Special torques, p. 10 - 2.
after 100 Lubricate the outrigger beams;
à Lubricating the outrigger beams, p. 7 - 128.
during the
first 100
Check the hydraulic oil filter every week,
and change it if necessary;
à Changing the hydraulic oil filter, p. 7 - 98.
after 100 after 1,000
(650)
Change the drive oil;
à p. 7 - 53 for the axle centre drives,
à p. 7 - 56for the final drives.
after 250 after 2,500
(1,550)
Change the engine oil;
à Engine manufacturer’s documentation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK 3060 and is the answer not in the manual?

Manitowoc GROVE GMK 3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK 3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals