Run-in regulations
03.11.2017
Maintenance manual 3 302 574 en 4 - 1
GMK3060
4 Run-in regulations
There are regulations about running in individual parts which must be
followed, after:
– First commissioning or
– Part replacement or
– General overhaul.
This is why
you must carry out additional main
tenance work on
the carrier
and superstructure at specific intervals:
s
Operating
hours
(oper. hrs.)
Driven km
(mi)
Additional maintenance work on the
CARRIER
After 50 (30)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
After 150
(95)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 50 Tighten the clips on the coolant hoses;
à Special torques, p. 10 - 2.
after 100 Lubricate the outrigger beams;
à Lubricating the outrigger beams, p. 7 - 128.
during the
first 100
Check the hydraulic oil filter every week,
and change it if necessary;
à Changing the hydraulic oil filter, p. 7 - 98.
after 100 after 1,000
(650)
Change the drive oil;
à p. 7 - 53 for the axle centre drives,
à p. 7 - 56for the final drives.
after 250 after 2,500
(1,550)
Change the engine oil;
à Engine manufacturer’s documentation.