Maintenance work on the carrier
7.14 Central lubrication system
03.11.2017
Maintenance manual 3 302 574 en 7 - 101
GMK3060
7.14 Central lubrication system
7.14.1 Checking the filling level
Grease, spare
parts, tools
Prerequisites – The parking brake must be applied.
Checking the
filling level
• Check the level in the grease container (1).
The filling level must be near the max. mark.
If it is below the min. marking, the level is
too low.
If the level is too low
• Top up with grease; à p. 7 - 102.
s
Lubricating
grease
Designation
to DIN 51502
Specification
Classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369
Designation Quantity GROVE part no.
Manual filling pump
(in the tool set supplied)
1