Maintenance work on the carrier
7.16 Air-conditioning system
03.11.2017
Maintenance manual 3 302 574 en 7 - 113
GMK3060
7.16 Air-conditioning system
7.16.1 Checking the air-conditioning system
• Switch on the air conditioning system; à Operating Instructions.
• Check that cooling takes place. If it does not, the air-conditioning system
is defective.
• Switch the air-conditioning system off.
If the air-conditioning system is defective
• Do not start it up again to avoid further damage.
Have the air-conditioning system repaired as soon as possible by
Manitowoc Crane Care or an authorised GROVE dealer or an authorised
specialist workshop.
7.16.2 Cleaning the condenser fins
• Switch the air-conditioning system off.
• Open the front flap (2); à Front flap, p. 7 - 2.
• Have the condenser fins (1) cleaned;
à p. 7 - 26.
S
Risk of damage to the condenser!
Do not use a high pressure cleaner or steam jet cleaner. The powerful jet
may damage the fins. Use only suitable cleaning agents air for cleaning.