Maintenance work on the carrier
7.14 Central lubrication system
03.11.2017
Maintenance manual 3 302 574 en 7 - 103
GMK3060
7.14.2 Bleeding the central lubrication system
If the grease container is empty or contains bubbles, you must bleed the
central lubrication system.
The grease container (1) is full.
Release the connection (3).
Trigger an intermediate lubrication by
pressing the button (2);
à Triggering
intermediate lubrication
, p. 7 - 103.
Repeat the procedure until the grease
flowing from the connection (3) no longer
contains any bubbles.
Fasten the connection (3).
Remove any grease that emerges.
7.14.3 Triggering intermediate lubrication
Intermediate lubrication should be triggered,
after high pressure cleaning,
to check the lubrication system at all lubricating points.
Switch on the ignition.
Remove the cover (1) and press the
button (2) for approx. 2 seconds.
An intermediate lubrication cycle will be trig-
gered which lasts approximately 3 minutes.
Check whether grease oozes from all the lubri-
catin
g points (steering lever on all axle lines).
Switch off the ignition.
Fasten the cover (1).
Remove any grease that emerges.