Maintenance work on the carrier
7.14 Central lubrication system
7 - 102 3 302 574 en Maintenance manual
GMK3060
03.11.2017
Topping up
Fill the grease container as follows:
• Switch on the ignition.
• Select one of these two connections (3).
• Remove the cap from the selected connec-
tion (3).
• Connect the filling pump to the connec-
tion (3).
• Trigger an intermediate lubrication by
pressing the button (2);
à Triggering inter-
mediate lubrication
, p. 7 - 103.
• Fill the grease container (1) up to the
max. marking.
• Remove the filling pump, wipe away any
grease that emerges and fasten the cap on
the connection (3).
S
Risk of damage to the central lubrication system!
Cleanliness is of the utmost importance when handling grease and filling
pumps.
Do not remove the caps from the opening and filling pump until immedi-
ately before refilling the grease. This prevents dirt particles from getting
into the grease
and damaging the central lubrication system.
1 Filling pump tool set:
(insert the grease cartridge into the
empty filling pump)
2 Filling pump for lubrication nipples