Maintenance work on the carrier
7.15 Electrical system
03.11.2017
Maintenance manual 3 302 574 en 7 - 109
GMK3060
Before checking
Switch the battery master switch (1) off and
remove the selector handle.
Open the cover (2) on the battery box.
Checking the acid concentration
Batteries without covers (1) are mainte-
nance-free.
Remove all covers (1).
Read off the cell value on the acid siphon (2)
and compare the value with that in the table;
à Charge level table, p. 7 - 108.
Check all cells in the same way.
Tightly screw on all covers (1).
After checking
Close the cover (2) on the battery box.
Attach the selector handle and switch on the
battery master switch (1).
Check the clocks on the tachograph and on
the auxiliary heater;
à Operating
Instructions
.
Enter the code for the radio; à Separate
operating instructions
.