Maintenance work on the superstructure
8.8 Hoist ropes
03.11.2017
Maintenance manual 3 302 574 en 8 - 49
GMK3060
The tables show by rope diameter the number of wire breaks in a length
6 times and 30 times the rope diameter which if reached would require
replacement of the rope.
• Familiarise yourself with DIN ISO 4309:2013-06 (rotation-resistant ropes).
This table applies only to the hoist ropes fitted as initial equipment and
original replacement ropes!
s
Number of visible wire breaks on a rotation-resistant hoist rope
The rope section runs over a rope disc or on a drum wound as a single layer
Number of
load-bearing
outer wires
 13 mm  16 mm
 17 mm
to
78 mm
to
390 mm
to
96 m
m
to
480 mm
to
102 mm
to
510 mm
101-120 3 5 3 5 3 5
12
1-140 3 5 3 5 3 5
 19 mm
 22 mm  24 mm
to
114 mm
to
570 mm
to
132 mm
to
660 mm
to
144 mm
to
720 mm
101-120 3 5 3 5 3 5
121-140 3 5 3 5 3 5
The rope section is running on a drum wound as multiple
layers
 13 mm
 16 mm  17 mm
to
78 m
m
to
390 mm
to
96 mm
to
480 mm
to
102 mm
to
510 mm
101-120 5 10 5 10 5 10
12
1-140 6 11 6 11 6 11
 19 mm
 22 mm  24 mm
to
114 mm
to
570 mm
to
132 mm
to
660 mm
to
144 mm
to
720 mm
101-120 5 10 5 10 5 10
121-140 6 11 6 11 6
11

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK 3060 and is the answer not in the manual?

Manitowoc GROVE GMK 3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK 3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals