Maintenance work on the superstructure
8.14 Other maintenance work
8 - 78 3 302 574 en Maintenance manual
GMK3060
03.11.2017
Spraying
• Make sure that you do not spray running
surfaces. There is a risk of slipping!
• Spray the corrosion protection with a spray
gun aimed only at the pumps, valve blocks,
screw connections, pipes, hoses of the
hydraulic system of the superstructure:
– On the slewing gear (1),
– On the slewing duct (2),
– On the derricking cylinder (3),
– On the hoists (4).
• Clean surfaces sprayed by accident
immediately with water.
• Let the corrosion protection dry for one hour.
• Check that a transparent waxy protective film has covered the entire
surface.
G
Risk of injury to the eyes!
While working with the spray extension you could be hit by the spray jet or
spray droplets. Wear protective goggles, protective clothing and gloves.