Maintenance overview
5.1 Maintenance intervals
5 - 2 3 302 574 en Maintenance manual
GMK3060
03.11.2017
The maintenance interval that occurs first determines when the next
maintenance is due.
–The driven km (or mi) can be taken from the speedometer.
–The operating hours (oper. hrs.) of the engine an power units of the
superstructure can be called up individually on the
CCS CCS display in the
crane cab.
The operating hours of the engine are equivalent to the total operating
hours of the superstructure.
The following table sets out the maintenance intervals for the maintenance
plans:
Please note that the long-term maintenance plans always incorporate
the short-term ones!
Mainte-
nance plans
Maintenance
interval
Driven km (mi)
(carrier)
Ope
rating hours
(oper. hrs.) of the
engine (super-
structure)
D
Daily / before
putting into
operation
W Weekly
M 1 monthly
approx. 2,000
(approx.
1,2
40)
100
M 3
every three
m
onths
5,000 – 6,000
(3,100 – 3,7
30)
250
M 6 every six
months
10,000 – 12,500
(6,
210 – 7,770)
500
M 12
every twelve
m
onths
20,000 – 25,000
(1
2,430 – 15,530)
10
00
Y 2 every 24 months
40,000 – 50,000
(2
5,000 – 31,000)
2000
Y 3 every 36
months 3000
Y 5 every 60 months
100,000
(62,00
0)
5000
Y 6 every 72 months 6000
Y 10 every 120 months
200,000
(124,0
00)
12 000