Maintenance overview
5.2 Maintenance plans
5 - 16 3 302 574 en Maintenance manual
GMK3060
03.11.2017
5.2.7 Maintenance plan Y 2
5.2.8 Maintenance plan Y 3
Y 2
Maintenance work on the CARRIER:
every 24 months / after 40 000 – 50 000 km (25,000 – 31,000 mi)
Engine
–Notes;
à Engine manufacturer’s documentation à p. 7 - 15
– Changing the coolant
à p. 7 - 30
Transmission
– Changing the oil
à p. 7 - 48
Other maintenance work
– Having the fire extinguisher checked
à p. 7 - 133
Maintenance work on the SUPERSTRUCTURE:
every 24 months/after 2 000 oper. hrs.
Other maintenance work
– Having the fire extinguisher checked
à p. 8 - 79
Y 3
Maintenance work on the CARRIER:
every 36 months
No maintenance work in this period.
The long-term intervals always include the short-term intervals!
Maintenance work on the SUPERSTRUCTURE:
every 36 months/after 3 000 oper. hrs.
Hoists
– Having a partial inspection carried out
à p. 8 - 14

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK 3060 and is the answer not in the manual?

Manitowoc GROVE GMK 3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK 3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals