Maintenance work on the carrier
7.3 Engine
7 - 20 3 302 574 en Maintenance manual
GMK3060
03.11.2017
Prerequisites – The truck crane is in on-road mode and the engine is running.
Checking The function test is performed via the CCS menu.
• Select and confirm the symbol (1).
The
Air intake inhibitor menu opens.
• Select and confirm the symbol (1) – symbol
is green.
• Select and confirm the symbol (2):
– The air intake inhibitor closes,
– The engine switches off,
– The warning lamp (3) lights up yellow.
The engine cannot be started while the air
intake inhibitor is closed.
• Attempt to start the engine:
– The starter motor must not turn over,
– The engine cannot start.
• Select and confirm the symbol (2):
– The air intake inhibitor opens,
– The warning symbol (3) goes out.
The engine can then be started again.
• Exit the function test – press the symbol (1)
– symbol is grey.
• Check that the engine can now be started
again.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK 3060 and is the answer not in the manual?

Manitowoc GROVE GMK 3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK 3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals