Installation and User Manual
78
7.3.2.6 FBK RST
function available from the software version 1.7
this parameter enables the automatic zero-setting
function of the Pulse Feedback value at the end of
each InProcess cycle.
1. Press
to access the FBK RST
programming:
2. Rotate the knob to enable or disable the
function:
• Yes = enabled (when the START CYCLE
machine input is disabled the pulse
feedback adjust value is reset
7.3.2.7 ADJ MODE
This parameter can be used to lock or release the Zero Adjust correction function for In-Process cycles when
the P3UP is in automatic mode.
1. Press
to set-up ADJ MODE;
2. Rotate the knob to lock or release the Zero
Adjust function:
• Locked – it is not possible to modify the
Zero Adjust in automatic mode
• Free = released, it is possible to modify
the Zero Adjust in automatic mode
3. Press
to confirm and return to the
programming menu; or
the programming menu without confirming.