7.3.2
Setting up the programming parameters (P3UP In-Process)
7.3.2.1 IP DELAY
This parameter can be used to define the length of the delay between the moment the P3UP receives the
START CYCLE signal from the machine logic and the moment when it actually starts measuring and
updating the controls.
[
N.B.
Once the delay time has elapsed the machine waits for the “settling time” (an additional interval
that is defined by a factory setting) before actually measuring the part.
1. Press
to set-up the
value;
2. Rotate the knob until the desired IP
DELAY value is reached;
3. Press to confirm and return to the
programming menu; or
to return to
the programming menu without
confirming.