7.3.3.4 Stock removal estimate memory
1. Press
to access the MEM T1 and MEM
T2 programming menu;
2. Rotate the knob to set-up the measurement
disable time (MEM T1) and the measurement
acquisition time (MEM T2) so as to obtain a
stable In-Process measurement.
3. Press
to confirm and return to the
programming menu; or
to return to the
programming menu without confirming.
[
N.B.
If the P3UP has been set-up by Marposs to allow the memory to function in "Sample&Hold only"
mode, the MEM T1 and MEM T2 fields do not appear in the programming menu.
[
N.B.
In manual mode it is possible to disable the memory by deactivating dynamic processing (DYN
LED Off). See paragraph 7.2.6.8.