20.2 Introducing acquisition / recording possibilities 173
5. Set the following sequencer set using "Sequencer Set Next" (brown box, figure 3): "Sequencer Set Next" =
"1".
6. Set the "Exposure Time" (red box, figure 3): "Exposure Time" = "1000".
7. Finally, save the "Sequencer Set" (green box, figure 3): "int SequencerSetSave()". This ends the configuration
of this sequencer set and all the relevant parameters have been stored inside the devices RAM.
8. Repeat these steps for the following 3 sequencer sets (Exposure Times 5000, 10000, 20000).
9. For the last sequencer set, set the desired sequencer set with "Sequencer Set Selector" (orange box, figure
4): "Sequencer Set Selector" = "4".
10. Set the following sequencer set with "Sequencer Set Next" and trigger source with "Sequencer Trigger
Source" (brown box, figure 4):
"Sequencer Set Next" = "0". This will close the loop of sequencer sets by jumping from here back to the first
one.
"Sequencer Trigger Source" = "Counter1End".
11. Set the "Exposure Time" (red box, figure 4): "Exposure Time" = "50000".
MATRIX VISION GmbH