TROUBLESHOOTING10 - 10
D-MAXE with OI-B/OI-N www.maxcessintl.comMI 2-296 1 D
Possible causes for faulty
behavior
Remedy Reference
Sensors Check the signals of the
connected sensors (range
±32767).
see item
Menu 1y.9.1.1
Sensors, page 7-57
in section
1y.9 Service
It may be necessary to
recalibrate the sensors.
see item
Menu 1y.5.1.1.1
Calibration, page 7-22
in
section
1y.5 Hardware IOs
See also the Operating Instructions for the relevant sensors
Are encoders being used? Check whether the encoders
are ’counting’.
see item
Menu 1y.9.1.2
Encoder, page 7-57
in section
1y.9 Service
For more information about the
encoders, refer to the
"Supplementary Operating
Instructions" in the system
documentation.
Are you using the correct
motor?
Check the motor see item
Menu 1y.5.2 Actuator,
page 7-41
in section
1y.5
Hardware IOs
and table
Actuators, page 11-8
For further information about
the motor refer to the system
diagram in the system
documentation.
A cursor appears below the
bar graph at the location to
which the guide point was
moved, together with a
numeric entry.
Is the offset of the guidepoint
set the way you want it?
Correct the guidepoint if
necessary.