VX30/VX50 Gen3/ECO50 Vacuum Systems Maintenance - 10 Service Hours or Daily 60-11
Coolant Level - Check
Step 1: Allow
cooling system to cool down.
Step 2: Remove fill cap (1) after radiator has
cooled.
Step 3: Fill when cool
ant is below LOW level in overflow tank (2). Fill with a
50/50 mixture of coolant and distilled or deionized water until overflow
tank level is between LOW and FULL marks.
NOTICE:
This machine was factory-filled with a 50/50 mixture of Shell Rotella
ELC NF (Extended Life Nitrite Free) coolant. Compatible coolants include
Chevron Delo ELC NF and Exxon Mobil Delvac ELC NF. Never add pure
antifreeze to the system; always dilute to a 50/50 mixture. Refer to the Engine
Operation Manual for further information.
WARNING: Hot fluid under pressure can erupt and scald if opened.
Allow to cool before opening.