Mercury 45 Jet 50-55 - Cleaning and Inspection of Trim Rod Components; Motor and Electrical Tests;Repair; Trim Pump Motor Test; Armature Tests

Mercury 45 Jet 50-55
564 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5D-20 - MID-SECTION 90-817643R1 DECEMBER 1996
3. Remove O-rings from cylinder.
51008
a
a - O-rings (2)
Cleaning and Inspection of
Trim Rod Components
CAUTION
Do not remove check ball components (a) from
trim rod piston. Removal and re-installation of
check valve could result in improper operating
pressure and possible power trim system dam-
age.
51199
a
Inspect check valve for debris; clean debris form
check valve if found. If debris cannot be cleaned from
check valve, replace trim rod piston as an assembly.
Clean trim rod and components with parts cleaner
and dry with compressed air.
It is recommended that all O-rings in trim system be
replaced.
Inspect trim rod. If scraper (located in cap) has failed
to keep rod clean, replace scraper.
Lubricate all O-rings using Quicksilver Power Trim
and Steering Fluid or; (ATF) Type F, FA or Dexron II.
Motor and Electrical
Tests/Repair
Trim Pump Motor Test
WARNING
Do not perform this test near flammables (or ex-
plosives), as a spark may occur when making
connections.
1. Disconnect green (motor) wire and blue (motor)
wire from trim system wiring harness.
2. Connect a 12 volt power supply to motor wires
(positive to blue; negative to green results in mo-
tor up direction. Positive to green; negative to
blue results in motor down direction). Motor
should run.
3. If motor does not run, disassemble motor and
check components.
Armature Tests
TEST FOR SHORTS
Check armature on a Growler (follow Growler man-
ufacturer’s test instructions). Indication of a short re-
quires replacement of armature.
TEST FOR GROUND
Use an Ohmmeter (R x 1 scale). Place one lead on
Ohmmeter on armature shaft and other lead on com-
mutator, as shown. If continuity is indicated, armature
is grounded and must be replaced.
51195

Table of Contents