114 Using the RFID Functions
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
Please note the following hints, if the automatic transponder position
measurement routine fails:
Note: Please always carry out several automatic transponder position
measurements. This is necessary to find the right transponder
position of your label material.
Defect
(Panel display)
Remedies
[No Tag Found ] The RFID tag was not found in the RF Field (area
inside the printer where RFID tag is read)
- check supply loading
- rerun the automatic transponder position
measurement
- further remedies are listed below
[Pos. Invalid ] The RFID tag was found in the RF Field, but could not
be read.
- increase the number of retries
See section 8.2.4 Adjusting the Number of
RFID Access.
- rerun the automatic transponder position
measurement
- Set the transponder position manually
(see next page).
- If there is still no proper access to the RFID tags
inspite of setting the right transponder position value
manually, please choose a different material.

Table of Contents