Panel Functions 93
________________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
7.28. Manual Sync Sensor Adjust
Manual adjusting of the Sync sensor level allows the processing of materials
with high contrast proof points within the label, which would otherwise be
falsely measured by the system.
The panel functions Sync Sens Level and Sensor Test \Gap serve to adjust
the contrast value measured by the Sync sensor specifically for the label
material in use.
The following describes the adjusting of a Gap sensor.
The steps to adjust a Reflex sensor are mostly comparable.
!
A contrast value of about 10% is appropriate for the masking
paper (level without label).
The measured level of label incl. masking paper has to be at least
twice as large as the value without label.
Higher contrast values are more advantageous so long as there is no rising of
the masking paper level.
If this conditions are not satisfied, you have to adjust the Sync sensor current
as well.