124 Using the RFID Functions
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
Parameters: Each rf command contains one or more type codes. Most of these
type codes are followed by an appropriate parameter.
Permissible values of the rf command parameters <k
xx
nn> :
Type
code
k
xx
Parameter
Description
00 no parameter
allowed
Terminate RFID processing
of the current label (label that is
below the RF Write/Read module of
the printer).
Please refer to the example in figure
8.4.1.a. This command can be used
to teminate RFID processing of label
B in order to cut label A immediately.
Hint: the ID number of label B is
available only if it was read
previously.
01 no parameter
allowed
Read ID
Reads the transponder (label ID
number), the answer is sent to the
host (via the printer SOLID status
channel; ASCII formatted).
11 nn = 2-digit
decimal
Data block number
When writing:
00 = EPC* = default
01 = user
When reading:
nn = block number
12 n = 1-digit
Data format
0 = binary = default
(ASCII presented as they are)
1 = Hex-ASCII
*EPC: Electronic Product Code