90 Panel Functions
________________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
7.26. Selecting the Light Sensor Type
The factory-fitted Gap Sensor (Transparent Photoelectric Switch) is
suitable for labels with transparent or register gaps (Menu sub-point Punched).
The optional Reflex Sensor (Reflex Photoelectric Switch) is suitable
for materials with markings / Black Marks (Menu sub-point Reflex).
OFFL.
MENU
NEXT
ENTER
NEXT
ENTER
ENTER
NEXT
ENTER
ESC
ENTER
ENTER
Panel display
[ON LINE ]
[OFF LINE ]
[Menu Level 1 ]
& & &
[Engine ]
[Printspeed ]
& & &
[Sync. Menu ]
[Sync.Sens.Type ]
[Punched ]
& & &
[Reflex ]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this
key.
The MENU key gives the user access
to the menu structure.
Press the NEXT or PREVIOUS key until
[Engine ] is displayed.
Press the NEXT or PREVIOUS key until
[Sync. Menu ] is displayed.
The currently set value is displayed.
Press the NEXT or PREVIOUS key until
the desired sensor type is displayed.
The reflex sensor is selected.
In addition this new value can be
saved as setup value (using the ENTER
key).
After this decision turn the printer ON
LINE again: Press the ENTER key
longer than 2 seconds.