92 Panel Functions
________________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
7.27.2. Example
In this example the steps to adjust the Gap Sensor are described.
OFFL.
MENU
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
ENTER
ESC
ENTER
ENTER
Panel display
[ON LINE ]
[OFF LINE ]
[Menu Level 1 ]
& & &
[Engine ]
[Printspeed ]
& & &
[Sync. Menu ]
[Sync.Sens.Type ]
& & &
[Auto.Sens.Adj. ]
[Put in Label ]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
The MENU key gives the user access to
the menu structure.
Press the NEXT or PREVIOUS key until
[Engine ] is displayed.
Press the NEXT or PREVIOUS key until
[Sync. Menu ] is displayed.
Press the NEXT or PREVIOUS key until
[Auto.Sens.Adj. ] is displayed.
Open the printhead and place label
(with masking paper) in the sensor area.
Close the printhead.
Press ENTER: the printer automatically
measures the contrast value.
In addition this new value can be saved
as setup value (using the ENTER key).
After this decision turn the printer ON
LINE again: Press the ENTER key longer
than 2 seconds.