13.1.2. Changing the Separator and Terminator Characters
The default settings for the separator and terminator are the following:
- Separator : SPACE (Hex 20)
- Terminator : NUL (Hex 00)
To change the default setting you have to set the word 30 within the
EEPROM sequence.
EEPROM word 30 : Bit 1 - 8 = Separator
Bit 9 - 16 = Terminator
Please use the IDOL command <ESC><ESC>ee for setting the word 30.
Example: Set the following configuration for the separator and terminator:
Separator should be the character " | " (ASCII 124, Hex 7C)
Terminator should be the character " # " (ASCII 35, Hex 23)
To set these values, you have to send the following sequence to the
printer:
<ESC><ESC>ee 030 237C
After power off and on the new values will be valid.