118 Using the RFID Functions
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
!
If Autom. Read ID is set to on *
3
, after the adjusting of the tag position the
label is read and the reading results are shown by the panel display.
9. Check if the ID number of your label material is read by the
printer.
!
!
You have always to perform several RFID reading tests with
different tag position settings to find the optimal tag position.
If, for example, the tag is read at the positions 50mm, 52mm and 54mm, at
each position you have to wait approximately 10 seconds to check if the tag
is read by the printer constantly.
If, for example, at the positions 50mm and 54mm the message „Read Time
Out“ or „Multi Tag Read“ is displayed shortly, this positions are not
interesting. (Using this RFID inlay the best reading position is in the middle.)
After setting the tag position to 52 mm please generate Test prints.
If the printing of 5 up to 10 test labels is successful, the optimal tag position
is found.
If the RFID inlay covers the whole label, the entire length of the label has to
be checked/tested in order to find the optimal tag position
(e.g. Frog-Inlay by UPM).
10. Select the option Save as Setup from the menu item [Tag Position ] to
save the optimized Tag Position as setup value.
*
3
Autom. Read ID = on is the factory default setting.
The panel function described in section 8.2.6 allows to change this setting.
The panel function [RFID Test ] can be used as well to read the label.