Using the RFID Functions 131
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
Examples: In the following status messages the character / is used as separator, the
character \ is used as terminator.
a) Reading the Label ID Number (Prior to the Print Process):
Command: &%&%rf 01
Status message: 1020/058000098B7C1F6B/\
This printer status message contains the following information:
Key-No. = 1020 : This is a answer to a RFID support command.
Label ID = 058000098B7C1F6B : Identification number of the label
(in this example the string includes 16 characters)
b) Generating a Page ID Number, Receiving the RFID data after Printing:
Command: &%&%: 0019 009 PAGE:0001
Status message: 1000/PAGE:0001/058000098B7C1F6B/\
This printer status message contains the following information:
Key-No. = 1000 : The label (one page) was printed well.
Page ID = PAGE:0001 : This is the page identification (page ID)
given by the user. See previous sections:
parameter of the status request command.
Label ID = 058000098B7C1F6B : Identification number of the label
(in this example the string includes 16 characters)