OM-267357 Page 53
Stick electrode must be firmly seated
in one of the two slots in the electrode
holder. Incorrect electrode place-
ment prevents accurate tracking of
the SmartStinger.
The stick electrode can be inserted in
either side of SmartStinger for 1G
and 2F positions. For all other posi-
tions (out-of-position welds), the
stick electrode must be inserted into
the side of the SmartStinger with no
buttons.
After tacking and calibrating the weld
joint, but before beginning to weld,
the user will be prompted to confirm
which electrode configuration is be-
ing used. Follow the instructions on
the monitor.
12-6. Stick Electrode Slot Confirmation