Chapter 4 Maintenance
4-31
6
Press the [END] key several times to end the operation.
Setting the Cleaning Interval
Cleaning type and the interval between each cleaning operation are set.
1
Select [AUTO MAINT.] of the MAINTENANCE menu.
(1) Press the [FUNCTION] key in LOCAL.
(2) Press to select [MAINTENANCE], and press the [ENTER] key.
(3) Press to select [AUTO MAINT.].
(4) Press the [ENTER] key.
2
Press to select [CLEANING].
AUTO MAINT.
[ENT]
CLEANING
3
Press the [ENTER] key.
CLEANING
: Lv. 1
4
Press to set the interval between each cleaning operation.
Available settings: OFF, Lv.1, Lv.2, Lv.3
As the level increases, the interval between each operation becomes shorter.
CLEANING
: Lv. 2
5
Press the [ENTER] key.
When you set a value other than "OFF" in Step 4, the cleaning type selection screen is displayed.
TYPE
: NORMAL
6
Press to select a cleaning type.
Available settings: NORMAL, SOFT, HARD
TYPE
: SOFT
7
Press the [ENTER] key.
AUTO MAINT.
[ENT]
CLEANING
8
Press the [END] key several times to end the operation.