Chapter 5 Troubleshooting
5-5
2
Set the ink bottle over the tank, and turn the tank lever from right to left.
• Move the tank lever completely to the right and set the ink bottle.
• Never rotate the ink bottle after setting it over the tank. Doing so may result in ink leakage.
3
Press the [ENTER].
If an error related to the sub tank occurs
Errors 618 to 61b are related to the sub tank.
Execute the following procedure when a sub tank error occurs, or when the nozzle is not unclogged after
cleaning.
1
Select [SUB TANK] of the MAINTENANCE menu.
(1) Press the [FUNCTION] key in LOCAL.
(2) Press to select [MAINTENANCE], and press the [ENTER] key.
(3) Press to select [SUB TANK].
2
Press the [ENTER] key.
SELECT SUBTANK
:CMYKYKMCClClWW
3
Press the [ENTER] key.
5