Chapter 5 Troubleshooting
5-10
Message Cause Solution
INK COLOR
: ---- YYKK
The color of ink in the ink
bottle is of a different type
than the currently supplied
ink.
Check the color of the ink bottle for
which the warning occurred.
WRONG INK BOTTLE
: ---- YYKK
An error occurred in the Ink
IC chip information of the
ink bottle.
Replace the ink bottle for which the
warning occurred.
NO INK BOTTLE
: ---- YYKK
Ink bottle is not set in the
external ink supply unit.
Set the ink bottle on the bottle
holder for which the warning
occurred.
EXPIRATION
: ---- YYKK
The specified expiration
date of the ink bottle has
passed.
The expiration date has passed.
However, you can use it until the
end of the following month.
Expiration:1MONTH
: ---- YYKK
The specified expiration
date of the ink bottle has
passed (one month has
passed after the expiration
date).
One month has passed after the
expiration date.
However, you can continue to use
it until the end of the month (the ink
bottle lamp blinks red).
Expiration:2MONTH
: ---- YYKK
The specified expiration
date of the ink bottle has
passed (two months have
passed after the expiration
date).
Two months have passed after the
expiration date.
Replace the cartridge for which the
warning occurred.
Error message
When an error message is displayed, eliminate the error according to the following table.
Message Cause Solution
CAN'T OPERATE
: INK ERROR
An ink error occurred. Check the ink bottle of the supply
path corresponding to the indicated
color.
CAN'T OPERATE
: DATA REMAIN
Data is being received. Clear the data.
"Deleting the Received Data
(Data Clear)" (P. 2-18)
ERROR 04
PARAM ROM
There is an abnormality in
the parameters.
Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 108
HD CONNECT [1 2 3 4 5 6 7 8 9 10 11 12]
Head connection cannot be
confirmed.
ERROR 108
HD THERMIS [1 2 3 4 5 6 7 8 9 10 11 12]
Head temperature cannot
be read.
ERROR 12a
HDC SPEED
Abnormality occurred in the
ink discharge waveform.
ERROR 12e
Head Failed [x x x x]
Abnormality of the head
and waveform driver
occurred.
ERROR 122
CHECK : SDRAM
There is no PRAM.
ERROR 128
HDC FIFO OVER
Data transmission
speed is too fast.
Control circuit board is
defective.
ERROR 128
HDC FIFO UNDER
Data transmission
speed is too slow.
Control circuit board is
defective.