Chapter 5 Troubleshooting
5-11
Message Cause Solution
ERROR 129
BATTERY EXCHANGE
Dead battery of internal
clock has been detected.
• Contact your local distributor, our
sales office, or service center.
ERROR 130
HD DATA SEQ
Head data transfer error
occurred.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 148
E-LOG SEQ
Sequential number
abnormality of the event log
occurred.
ERROR 151
Main PCB V1R2
Error occurred in the 1.2 V
power supply to the main
PCB.
ERROR 152
Main PCB V2R5
Error occurred in the 2.5V
power supply to the main
PCB.
ERROR 153
Main PCB V3R3
Error occurred in the 3.3V
power supply to the main
PCB.
ERROR 154
Main PCB V05
Error occurred in the 5V
power supply to the main
PCB.
ERROR 155
Main PCB V35-1
Error occurred in the main
PCB 35-1 V power supply.
ERROR 156
Main PCB V5B
Error occurred in the main
PCB 5 VB power supply.
ERROR 157
Main PCB VTT
Error occurred in the main
PCB VTT power supply.
ERROR 158
Main PCB V352
Error occurred in the main
PCB 35-2 V power supply.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 15f
HEAD DRIVE HOT
COM driver is hot.
ERROR 16e
Main PCB V3R3B
Error occurred in the main
PCB 3.3 VB power supply.
ERROR 171
NEW HEAD CONNECT
New head connection was
recognized.
ERROR 172
Main PCB Q6 Check
The main PCB Q6 has
malfunctioned (short
mode).
ERROR 186
HDC OVERFLOW
Error detected in the print
waveform.
ERROR 186
HDC UNDERFLOW
ERROR 187
HDC SLEW RATE
ERROR 188
HDC MEMORY
ERROR 18a
Main PCB V_CORE
Error occurred in the main
PCB power supply.
ERROR 18b
Main PCB V1R5B
Error occurred in the 1.5 V
power supply to the main
PCB.
ERROR 18b
Main PCB V12
Error occurred in the 12V
power supply to the main
PCB.
5