Chapter 5 Troubleshooting
5-12
Message Cause Solution
ERROR 18e
FLS NOT COMP [1 2 _ _]
An error occurred in the
flushing control.
ERROR 18f
OFFSET START [1 2 _ _]
An error occurred in the
head voltage control.
ERROR 18f
OFFSET END [1 2 _ _]
ERROR 19d
HDC V36 [1 2 _ _]
An error occurred in the
HDC circuit board voltage.
ERROR 19f
LED CONNCT ERR: ******
The LED UV is not
connected.
ERROR 201
COMMAND
The machine received
some data other than the
command data.
• Securely connect the interface
cable.
Use an interface cable conforming
to the specifications.
ERROR 202
PARAMETER
Parameter outside the
range of acceptable
numeric values was
received.
ERROR 203
Ment Command
A maintenance command
error occurred.
ERROR 304
USB INTI ERR
USB device initialization
failure.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 305
USB TIME OUT
Timeout error occurred in
the USB device.
ERROR 401
MOTOR X
Excessive load was applied
to the X motor.
ERROR 402
MOTOR Y
Excessive load was applied
to the Y motor.
ERROR 403
X CURRENT
An error due to excessive
current of X motor was
detected.
ERROR 404
Y CURRENT
An error due to excessive
current of Y motor was
detected.
ERROR 444
Replace Ymotor Brush
Time to replace the brush
of Y motor.
• The brush of Y motor needs to be
replaced.
Contact your local distributor, our
sales office, or service center.
ERROR 505
MEDIA JAM
Media has jammed. • Take out the media and reset it.
ERROR 509
HDC POSCNT
HDC position counter error
occurred.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 50a
Y ORIGIN
Y origin could not be
detected.
ERROR 50f
L-SCALE BLACK
Abnormality occurred in
linear scale.
ERROR 510
X ORIGIN
X origin could not be
detected.
ERROR 519
NEGATIVE P.SENSOR
The value of negative
pressure sensor is
abnormal.
• Adjust the pressure.
"If pressure abnormality
occurs" (P. 5-6)
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 51a
POSITIVE P.SENSOR
The value of positive
pressure sensor is
abnormal.