Chapter 5 Troubleshooting
5-12
Message Cause Solution
ERROR 18e
FLS NOT COMP [1 2 _ _]
An error occurred in the
flushing control.
ERROR 18f
OFFSET START [1 2 _ _]
An error occurred in the
head voltage control.
ERROR 18f
OFFSET END [1 2 _ _]
ERROR 19d
HDC V36 [1 2 _ _]
An error occurred in the
HDC circuit board voltage.
ERROR 19f
LED CONNCT ERR: ******
The LED UV is not
connected.
ERROR 201
COMMAND
The machine received
some data other than the
command data.
Securely connect the interface
cable.
Use an interface cable conforming
to the specifications.
ERROR 202
PARAMETER
Parameter outside the
range of acceptable
numeric values was
received.
ERROR 203
Ment Command
A maintenance command
error occurred.
ERROR 304
USB INTI ERR
USB device initialization
failure.
Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 305
USB TIME OUT
Timeout error occurred in
the USB device.
ERROR 401
MOTOR X
Excessive load was applied
to the X motor.
ERROR 402
MOTOR Y
Excessive load was applied
to the Y motor.
ERROR 403
X CURRENT
An error due to excessive
current of X motor was
detected.
ERROR 404
Y CURRENT
An error due to excessive
current of Y motor was
detected.
ERROR 444
Replace Ymotor Brush
Time to replace the brush
of Y motor.
The brush of Y motor needs to be
replaced.
Contact your local distributor, our
sales office, or service center.
ERROR 505
MEDIA JAM
Media has jammed. Take out the media and reset it.
ERROR 509
HDC POSCNT
HDC position counter error
occurred.
Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 50a
Y ORIGIN
Y origin could not be
detected.
ERROR 50f
L-SCALE BLACK
Abnormality occurred in
linear scale.
ERROR 510
X ORIGIN
X origin could not be
detected.
ERROR 519
NEGATIVE P.SENSOR
The value of negative
pressure sensor is
abnormal.
Adjust the pressure.
"If pressure abnormality
occurs" (P. 5-6)
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 51a
POSITIVE P.SENSOR
The value of positive
pressure sensor is
abnormal.

Table of Contents