Chapter 5 Troubleshooting
5-13
Message Cause Solution
ERROR 617
SUB TANK: 1 2 3 4 5 6 7 8 9 10 11 12
Liquid level sensor
abnormality of the sub tank
has been detected.
Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 618
LevelH: 1 2 3 4 5 6 7 8 9 10 11 12
Though certain amount was
consumed, there is no
change in the sub tank
sensor error indicating high
level.
Perform sub tank maintenance.
If an error related to the sub tank
occurs
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 619
LevelL: 1 2 3 4 5 6 7 8 9 10 11 12
Though certain amount was
consumed, there is no
change in the sub tank
sensor error indicating low
level.
ERROR 61a
Overflow: 1 2 3 4 5 6 7 8 9 10 11 12
Ink overflow from the sub
tank has been detected.
ERROR 61b
SUPPLY: 1 2 3 4 5 6 7 8 9 10 11 12
Ink could not be supplied to
the sub tank.
Adjust the pressure. Also check the
remaining amount of ink in the ink
bottle.
If an error related to the sub tank
occurs
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 61c
NEGATIVE P.CONTROL
Abnormality in the starting
of negative pressure
control.
Adjust the pressure.
"If pressure abnormality
occurs" (P. 5-6)
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 61d
NEGATIVE P.NotEnough
Negative pressure cannot
be maintained.
ERROR 61e
NEGATIVE P.OVER
ERROR 61f
POSITIVE P.CONTROL
Abnormality in the starting
of positive pressure control.
ERROR 620
POSITIVE P.NotEnough
Positive pressure cannot be
maintained.
ERROR 621
PPOSITIVE P.OVER
ERROR 637
INK LEAK 1 --
Ink leak detected in ink
supply route.
Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 702
THERMISTOR
The thermistor is defective.
ERROR 706
DRV OVHT 0**0**
UVLED Driver circuit board
is hot.
ERROR 707
!HD HEATER BREAK
Head heater is
disconnected.
ERROR 711
LED OVHT 0**0**
UVLED circuit board is hot.
ERROR 714
INK HEATER COM ERR
Communication error of ink
heater circuit board
ERROR 715
InkHeaterRThr: 12
Ink heater thermistor is
defective.
ERROR 715
InkHeaterFThr: 12
5