Chapter 5 Troubleshooting
5-8
Warning/Error Message
When an abnormality occurs, the buzzer rings and the display shows a corresponding message.
Take measures according to the message.
Warning message
Errors when performing operations
Message Cause Solution
CAN'T OPERATE
: INK ERROR
An ink error occurred. • Check the ink bottle of the supply
path corresponding to the indicated
color.
CAN'T OPERATE
: DATA REMAIN
Data is being received. • Clear the data.
"Deleting the Received Data
(Data Clear)" (P. 2-18)
Message displayed in LOCAL
Message Cause Solution
<LOCAL>
CAN'T PRINT/CART. [ENT]
Multiple ink errors
(unusable ink).
Ink supply (printing,
cleaning) cannot be
performed.
• Press the [ENTER] key to check
the ink bottle generating the error
and the error details. Replace the
ink bottle with a usable one.
<LOCAL>
Check waste ink [MNT]
Waste ink tank is nearly full. • Check the waste ink tank.
<LOCAL>
Replace a WIPER [MNT]
Time to replace the wiper in
the capping station with a
new one.
(The wiping count has
reached the specified
value)
• Press the [MAINT.] key and
replace the wiper with a new one.
"Replacing the wiper" (P. 4-32)
<LOCAL>
DATA REMAIN
The data has been
received.
• Press the [REMOTE] key to
perform printing.
Or, clear the data.
"Deleting the Received Data
(Data Clear)" (P. 2-18)
<LOCAL>
WATER LACK
Water in the cooling water
tank is low.
• Refill the coolant.
Refilling the Coolant
<LOCAL>
REFILL WATER
Water in the cooling water
tank has been low for more
than seven days.
• Refill the coolant.
Refilling the Coolant
• Online printing cannot be
performed while this warning is
displayed.
<LOCAL>
UV LAMP TEMP. HIGH
LED lamp temperature is
high.
• Wait until the temperature lowers
and the message disappears.
<LOCAL>
NEGATIVE PRESSURE
The value of negative
pressure sensor is
abnormal.
• Adjust the pressure.
"If pressure abnormality
occurs" (P. 5-6)
• If the pressure cannot be adjusted
to a normal value or if the message
is displayed even after executing
this step, contact your local
distributor, or our sales office or
call center.
<LOCAL>
POSITIVE PRESSURE
The value of positive
pressure sensor is
abnormal.