Chapter 3 Convenient Usage
3-9
Adjusting the Bidirectional Print
Drop Position
If you change the printing conditions (such as media thickness and head height), do the following to correct
the ink drop position for bidirectional printing (Bi) to acquire the proper printing results:
Correcting the Drop Position
1
Set the media and set the print origin.
"Setting up the Media" (P. 2-5)
2
In LOCAL, press the [ADJUST] key twice.
DROP.POScorrect
[ENT]
3
Press the [ENTER] key.
DROP.POScorrect
: Y300 dpi
4
Press to select the resolution.
Available settings: Y300dpi/Y600dpi/Y1200dpi
Make the correction for all the resolutions.
DROP.POScorrect
: Y600 dpi
5
Press the [ENTER] key.
DROP.POScorrect
[ENT]
PRINT START
6
Press the [ENTER] key to start pattern print.
The test pattern is printed. (They are called pattern 1, 2, 3... in the order in which they were
printed)
**PRINT**
PLEASE WAIT
3

Table of Contents