Chapter 5 Troubleshooting
5-14
Message Cause Solution
ERROR 716
InkHeaterRTmp: 12
Abnormality in ink heater
temperature.
• Turn off the power on the machine
and turn it on after a while.
When power is ON, the screen for
selecting whether to control the ink
heater is displayed. [>] Press the
(START) key and start the ink
heater control.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 716
InkHeaterFTmp: 12
ERROR 717
InkHeaterRBrk: 12
Ink heater was
disconnected.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 717
InkHeaterFBrk: 12
ERROR 718
InkHeaterPCB Thr: 12
Thermistor of the
InkHeaterPCB is defective.
ERROR 719
InkHeaterPCB Fuse: 12
InkHeaterPCB Fuse has
blown .
ERROR 71a
UV-DRV Fuse: ******
Fuse of the UVLED Driver
circuit board has blown.
ERROR 902
DATA REMAIN
There is remaining received
data that has not been
printed yet.
• Clear the data.
"Deleting the Received Data
(Data Clear)" (P. 2-18)
ERROR 90d
NO HEAD SELECT
The number of installed
heads is 0.
• Turn off the power on the machine
and turn it on after a while.
If displaying again, contact your
local distributor, our sales office, or
service center.
ERROR 910
ROOM TEMP./LOW
Ambient temperature is
outside the allowable range
(low).
• Adjust the ambient temperature of
the place where the machine is
installed.
ERROR 911
ROOM TEMP./HIGH
Ambient temperature is
outside the allowable range
(high).
SYSTEM HALT
Message Solution
SYSTEM HALT (*).
000: MESSAGE
• Turn off the power on the machine and turn it on after a while.
Check the error number, and contact your local distributor, or our
sales office or call center. ("000" is the error number.)