Chapter 4 Maintenance
4-41
2
Remove the water supply/drainage cap.
Water supply/
drainage
Air purge
3
Prepare mixed water solution (antifreeze liquid:1, water: 2) in the provided container and fill it
into the provided syringe.
4
Fill the mixed water solution until the buzzer sound stops.
Fill the mixed water solution through the water inlet using a syringe.
Fill an additional 100 CC after the buzzer stops.
The mixed water solution will leak from the tank if you inject it too much.
5
Close the water inlet and air purge, and attach the cover of the left rear side of Y-bar.
4