4-20
5
Register the Nozzle number that needs NOZZLE
RECOVERY and then press key.
(1) Select the registration number from 1 to 10 by pressing
key and press the .
(2) Register the nozzle number that needs recovery by pressing
key and press the .
• Check is performed at the same time of the registration. When
there is a mode for which nozzle recover is invalid, the screen of
the Step 3 of “Check the print condition for which nozzle recovery
cannot be performed”.
6
Press the key several times to end the setting.
• Up to 10 nozzles can be registered per 1 nozzle line.
• Even if you use this function, time required for drawing does not change.
• Depending on the print mode, the nozzle recovery function becomes invalid. When the nozzle
recovery function becomes invalid, you cannot print with an alternative nozzle.
Confirm the list of “Valid/ invalid of nozzle recovery function in each print mode”, and print with the
print mode where the nozzle recovery function is valid.
• In addition, even in the print mode where the nozzle recovery function is valid, recovery may not be
reflected depending on the registered nozzle. Check the print condition where the recovery cannot be
performed in the check function, and then select the print mode. ( P.4-23)
Nozzle missing
No.184
Nozzle
number
Nozzle missing
No.16
Nozzle missing
No.128
Registration
number
Recovery
Nozzle No.
State
116
Target for nozzle recovery
2 128
Target for nozzle recovery
3 184
Target for nozzle recovery
4 OFF
No registration
5OFF
No registration
Example of nozzle to be recovered