4-10
5
Press the key.
• The carriage moves onto the platen.
6
Clean the cap rubber and cap rubber cover.
• Wipe off the ink sticking to the cap rubber and cap rubber
cover with a clean stick dipped in cleaning solution for
maintenance. Wipe off so that cleaning solution for
maintenance will not remain.
• At this time, the discharge passage is cleaned automatically.
7
Press the key.
8
Fill up the cap with cleaning solution for maintenance
.
• Take the maintenance washings to a dropper, and fill the cap.
Fill the cap with the washings just until the washings
overflows from the cap.
9
Close the right maintenance cover and press the
key.
10
Press to set the time for the cleaning
solution to be left as it is.
• Set Value:1 to 99 min (by the unit of 1 min)
• Until wiper cleaning is competed, [COMPLETED (NEXT): ENT] is displayed on the screen. After
the work up to the step 6 is completed, press the key. If you press the key
before cleaning is completed, the machine moves to the next washing procedure.
• Until washing liquid is filled, [COMPLETED (NEXT): ENT] is displayed on the screen. After the
work up to the Step 6 is completed and you close the right maintenance cover, press the
key. If you press the key before washing liquid is filled, the carriage returns
to the original position.