Test mode Description
"External" Deactivated PLC:
- The physical inputs are displayed (dis-
play).
- Output values can be entered.
- The given output values are set on the
physical outputs.
9.1.2.1 Adapting the analog output
The output current can be adapted in small ranges. This is required, if small deviations
from the nominal value occur in a connected PLC.
Open the menu with - [HW-Slots].
1. Select and conrm the analog output.
2. Press the [Adjust] softkey.
The window for the 1st value opens.
Transmitter Series PR 5220 9 Extended functions