SPM address Type of data R/W Function
D10 DINT R Current tare weight
D11 DINT R Current gross/net weight selected with X72
D14 DINT R Max. weight (FSD)
D15 DINT R Min. weight
D16 DINT R Report: Gross weight
D17 DINT R Report: Net weight
D18 DINT R Report: Tare weight
D19 DINT R Report: Sequence number
D21 DINT R Report: Date
D22 DINT R Report: Time
D23 DINT R Activity counter, test of communication with device
D24 DINT R Standard application only: Limit: Limit 1 on
D25 DINT R Standard application only: Limit: Limit 1 o
D26 DINT R Standard application only: Limit: Limit 2 on
D27 DINT R Standard application only: Limit: Limit 2 o
D28 DINT R Standard application only: Limit: Limit 3 on
D29 DINT R Standard application only: Limit: Limit 3 o
D30 UDINT R/W Standard application only: Analog output for "transparent" mode
D31 DINT R/W Write the value in the preset tare memory.
B144
X1152
X1153
X1154
X1155
BYTE
BOOL
BOOL
BOOL
BOOL
R
R
R
R
R
EasyFill only: Filling status 1
Filling mode active
Filling mode ready (ready/idle)
Filling mode error
Filling mode in setup
B145
X1160
X1161
X1162
X1163
X1164
X1165
BYTE
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
R
R
R
R
R
R
R
EasyFill: Filling status 2
Filling in progress
Filling paused
Coarse ow
Fine ow
Calming
Tolerance alarm
Transmitter Series PR 5220 13 SPM
Minebea Intec EN-214