4.4.7.3 Connecting a load cell with a 6-wire cable
Terminal Port/color code Description
SIGN. M+ + Meas./gn + Signal (LC output)
SIGN. M- - Meas./gy - Signal (LC output)
SENSE S+ + Sense/wh + sense
SENSE S- - Sense/bk - Sense
LC SUPPLY V+ + Supply/rd + Supply (excitation)
LC SUPPLY V- - Supply/bu - Supply (excitation)
LC SUPPLY
Grounding Screen (ground)
4.4.7.4 Connecting 28 load cells (650 ) using a 6-wire connecting cable
Connections are made via junction box PR 6130/.. using connection cable PR 6135/.. or
PR 6136/... .
Load cell supply circuit
- Load resistance of load cell circuit ≥75 , e.g. 8 load cells of 650 each
- Supply voltage is xed to 12 V DC and protected against short circuit.
For further technical data, see Chapter 17.5.1.