5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.8 Compatible Devices with SSCNETIII(/H)
275
5
If the optical hub unit is connected to a sub route, an error occurs, and the optical hub unit does not
communicate with the Motion CPU.
A servo amplifier can be connected between two optical hub units, and between a Motion CPU and an
optical hub unit.
When turning OFF the control circuit power supply of SSCNET/H compatible equipment connected to an
optical hub unit, use the "connect/disconnect function of SSCNET communication". Refer to connect/
disconnect function of SSCNET communication for details of "connect/disconnect function of SSCNET
communication". (Page 184 Connect/disconnect function of SSCNET communication)
Restrictions on SSCNET communication
Set the communication type to "SSCNET/H" for the SSCNET setting connecting the optical hub unit. SSCNET/H
communication equipment set in MT Developer2 can be connected. There are no restrictions on connection order or
connection position. The servo amplifiers and SSCNET/H compatible equipment that can be used with the optical hub
unit are shown below.
: Available, : Not available
SSCNET setting Servo amplifier SSCNETIII/H compatible
equipment
MR-J4(W)-B MR-J3(W)-B
SSCNET/H 
SSCNET