APPENDICES
Appendix 1 Error Codes
393
A
1BE5H Main shaft clutch
reference address setting
outside range
A value outside the range of 0 to 1 was set in synchronous
parameter "[Pr.406] Main shaft clutch reference address
setting".
Set within the range of 0 to 1.
1BE6H Main shaft clutch
smoothing method outside
range
A value outside the range of 0 to 5 was set in synchronous
parameter "[Pr.411] Main shaft clutch smoothing system".
Set within the range of 0 to 5.
1BE7H Main shaft clutch
smoothing time constant
outside range
A value outside the range of 0 to 5000 was set in
synchronous parameter "[Pr.412] Main shaft clutch
smoothing time constant".
Set within the range of 0 to 5000.
1BE8H Composite main shaft
gear operation overflow
The composite value is overflowed (sign reverse)
because the input values of main input axis and sub input
axis are large.
Lower the input values of main input axis and sub input
axis.
1BE9H Main shaft clutch control
setting error
The control cycle setting of the high-speed input request
signal set in synchronous parameter "[Pr.405] Main shaft
clutch control setting" does not match the control
operation cycle of output axis.
Set the high-speed input request signal whose control
cycle setting matches the control operation cycle of output
axis.
1BF0H Auxiliary shaft number
outside range
• The setting value of synchronous parameter "[Pr.418]
Auxiliary shaft number" is outside the setting range.
• The same servo input axis number as the output axis is
set in the synchronous parameter "[Pr.418] Auxiliary
shaft number".
• Set within the range.
• Do not set the same servo input axis number with
output axis.
1BF2H Auxiliary shaft gear
denominator outside range
Set the value of synchronous parameter "[Pr.421]
Auxiliary shaft number denominator" less than 0.
Set within the range of 1 to 2147483647.
1BF3H Auxiliary shaft gear
operation overflow
The input value is overflowed (sign reverse) because of
the gear ratio of auxiliary shaft gear is large.
• Reduce the absolute value of synchronous parameter
"[Pr.420] Main shaft gear numerator ".
• Increase the synchronous parameter "[Pr.421] Main
shaft gear denominator".
• Slow down the input axis speed."
1BF4H Auxiliary shaft clutch
setting outside range
The value of synchronous parameter "[Pr.422] Auxiliary
shaft clutch control setting" is outside range.
Set within the range.
1BF5H Auxiliary shaft clutch
reference address setting
outside range
A value outside the range of 0 to 1 was set in synchronous
parameter "[Pr.423] Auxiliary shaft clutch reference
address setting".
Set within the range of 0 to 1.
1BF6H Auxiliary shaft clutch
smoothing method outside
range
A value outside the range of 0 to 5 was set in synchronous
parameter "[Pr.428] Auxiliary shaft clutch smoothing
system".
Set within the range of 0 to 5.
1BF7H Auxiliary shaft clutch
smoothing time constant
outside range
A value outside the range of 0 to 5000 was set in
synchronous parameter "[Pr.429] Auxiliary shaft clutch
smoothing time constant".
Set within the range of 0 to 5000.
1BF8H Composite auxiliary shaft
gear operation overflow
The composite value is overflowed (sign reverse)
because the input values of main shaft and auxiliary shaft
are large.
Lower the input values of main shaft and auxiliary shaft.
1BF9H Auxiliary shaft clutch
control setting error
The control cycle setting of the high-speed input request
signal set in synchronous parameter "[Pr.422] Auxiliary
shaft clutch control setting" does not match the control
operation cycle of output axis in synchronous controlling.
Set the high-speed input request signal whose control
cycle setting matches the control operation cycle of output
axis.
1C00H Speed change gear 1
arrangement outside
range
A value outside the range of 0 to 3 was set in synchronous
parameter "[Pr.434] Speed change gear 1 arrangement".
Set within the range of 0 to 3.
1C01H Speed change ratio 1
den
ominat
or outside range
Set the value of synchronous parameter "[Pr.437] Speed
change ratio 1 denominator" less than 0.
Set within the range of 1 to 2147483647.
1C02H Speed change gear 1
smoothing time constant
outside range
A value outside the range of 0 to 5000 was set in
synchronous parameter "[Pr.435] Speed change gear 1
smoothing time constant".
Set within the range of 0 to 5000.
1C03H Speed change gear 1
operation overflow
The input value is overflowed (sign reverse) because of
the speed change ratio of speed change gear 1 is large.
• Reduce the absolute value of synchronous parameter
"[Pr.436] Speed change ratio 1 numerator".
• Increase the synchronous parameter "[Pr.437] Speed
change ratio 1 denominator".
• Slow down the input axis speed.
1C04H Speed change gear 2
arrangement outside
range
A value outside the range of 0 to 3 was set in synchronous
parameter "[Pr.490] speed change gear 2 arrangement".
Set within the range of 0 to 3.
Error
code
Error name Error details and cause Corrective action