402
APPENDICES
Appendix 1 Error Codes
3919H MVPST execution error Internal processing error occurred when MVPST is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391AH MVLOAD execution error Internal processing error occurred when MVLOAD is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391BH MVTRG execution error Internal processing error occurred when MVTRG is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391CH MVIN execution error Internal processing error occurred when MVIN is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391DH MVFIN execution error Internal processing error occurred when MVFIN is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391EH MVCLOSE execution error Internal processing error occurred when MVCLOSE is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
391FH MVCOM execution error Internal processing error occurred when MVCOM is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3920H SET execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3921H RST execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3922H SET= execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3923H RST= execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3924H DOUT execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3925H DIN execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
3926H OUT= execution error The device number which indirectly specifies (D) is illegal. Correct the program so that the device number which
indirectly specifies (D) is proper.
392EH FOR (assign) execution
error
Internal processing error occurred when FOR
(assignment) is executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3930H Bit opposite
(complemented) execution
error
Internal processing error occurred when bit which is in a
value is flipped to its opposite setting (complemented) is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3931H Bit AND execution error Internal processing error occurred when bit AND is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3932H Bit OR execution error Internal processing error occurred when bit OR is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3933H Bit XOR execution error Internal processing error occurred when bit XOR is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3934H Bit right-shifted execution
error
Internal processing error occurred when bit right-shifted is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3935H Bit left-shifted execution
error
Internal processing error occurred when bit left-shifted
is executing.
The Mot
i
on SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3940H NOT/OFF execution error Internal processing error occurred when NOT/OFF is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
3941H AND execution error Internal processing error occurred when AND is
executing.
The Motion SFC program code is corrupted. Turn
"[Rq.1120] PLC ready flag" OFF and write the Motion SFC
program again.
Error
code
Error name Error details and cause Corrective action