8
PARAMETERS
8.1 PLC Parameters
8.1.2 High Performance model QCPU, Process CPU, Redundant CPU
8
- 17
1
Overview
2
Performance
Specification
3
Sequence Program
Configuration and
Execution Conditions
4
I/O Nunber Assignment
5
Memories and Files
Handled by CPU Module
6
Functions
7
Communication with
Intelligent Function
Module
8
Parameters
(3) PLC file
Set various files used by the CPU module.
Diagram 8.14 PLC file
Table8.14 PLC file list
Item Parameter No. Description Setting range Default value Reference
File register 1100
H
Set the file register file used by
the program.
• Do not use
• Use the same file name as
that of the program
• Use the following file
Do not use Section 9.7
Comment file used in a
command
1101
H
Set the device comment file
used by the program.
• Do not use
• Use the same file name as
that of the program
• Use the following file
Do not use ----
Initial Device value 1102H
Set the device initial value file
used by the CPU module.
• Do not use
• Use the same file name as
that of the program
• Use the following file
Do not use Section 6.26
File for local device 1103
H
Set the local device file used by
the program.
• Do not use
• Use the following file
Do not use Section 9.13.1