Dansensor® Lippke® 5000 EN User Guide 39
P/N 380419-C
05/2022
Burst test
A Burst test checks the strength of a package sealing by increasing the pressure in the
package until it bursts. The Burst test is compliant with ASTM F2054.
CAUTION! As the bursting of the test package may lead to considerable noise, we
recommend wearing hearing protection.
NOTE! When testing filled packages, precautions may be necessary to ensure that
the product does not contaminate the operator or the system. Depending on the
package contents, the use of safety glasses may be advisable. A protective hood
placed over the package may offer additional protection.
A Burst test is divided into 2 phases:
The package is inflated to the set pre-fill pressure.
The pressure in the package is increased at the pre-set rate until the package bursts or
until the maximum specified pressure is reached.
The results from the Burst test are:
Measured burst pressure (if the package bursts).
PASS - if the package bursts within the pre-set burst limits.
FAIL - if the package bursts outside the pre-set burst limits or does not burst at all.
CAUTION! If the package did not burst, it is still under pressure! Stop the test and
then remove the package carefully; a sudden pressure drop will occur when it is
removed.
1SFTTVSF
5JNF
-JNJU.BY#VSTU1SFTTVSF1
.BY1SFTTVSF1NBY
#VSTUQSFTTVSF
-JNJU.JO#VSTU1SFTTVSF1
1SFöMM1SFTTVSF1
<NCBS>
<TFD>
*OøBUJOHUPQSFöMMQSFTTVSF
-JOFBSQSFTTVSFJODSFBTF
<*OøBUJPO3BUF15>