PARISON CONTROLLER
moog
12 MAN145-UM-D01A-EN Moog Italiana srl - Bergamo
2.1.3 Display Led panel.
Start: Lit when the cycle Start (1 or 2) signal is received.
Die gap: Lit when the Die Gap signal is received (only in position accumulator
mode).
Continuous: Lit when the “Continuous Extrusion” machine type is selected.
Accumulator: Lit when “Accumulator” machine type is selected.
Divergent: Lit when “Divergent” die is selected. Normally it is reported to the
head number 1. If the work page visualizes another head this led reports to this
same head.
Convergent: Lit when “Convergent” die is selected. Normally it is reported to
the head number 1. If the work page visualizes another head this led reports to
this same head.
End of filling: Lit at the end of the accumulator filling (only in position accumulator mode).
Point out: Lit when each serial marker point is reached.
End of extrusion: Lit at the end of extrusion. (both in continuous extrusion and accumulator mode)